2) Pump mounting
Before mounting the pump, install the brass 90 degree fitting on the inlet of the pump,
use the larger of the two fittings provided. The top of the pump will be marked with an
arrow indicating flow direction. Next install the smaller 90 degree brass fitting on the
outlet of the pump. Careful when tightening these fittings as the housing on the pump
can break. Rule of thumb, tighten by hand then one full turn. The mounting location
for the pump will be in the wheel well behind the drivers side front tire. Use the
supplied 4 self tapping screws to attach pump, if drilling into chassis metal, attach o-
ring to one of the bolts before its drilled into place. This will ground it. Now install the
short 18 inch feed hose. Next, on the outlet attach 32 inch section of hose. Pump is to
be mounted with its head pointing down to the ground so access to adjustment screw
can latter be made if needed.